Difference between revisions of "Trackables pane"

(HMD Calibration)
(Steps)
Line 26: Line 26:
 
# [Motive] Create a rigid body asset from the markers on the oculus HMD. Read: [[Rigid Body Tracking#Creating Rigid Body|Creating Rigid Body]].
 
# [Motive] Create a rigid body asset from the markers on the oculus HMD. Read: [[Rigid Body Tracking#Creating Rigid Body|Creating Rigid Body]].
 
# [Motive] Open the Trackables pane. ''Tools → Trackables → HMD Calibration tab''
 
# [Motive] Open the Trackables pane. ''Tools → Trackables → HMD Calibration tab''
# [Motive] Select the HMD rigid body.
+
# [Motive] Select the HMD rigid body. Under ''Detected Type'', it should indicate ''Custom RigidBody''.
 
# [Motive → Trackables pane] Set the desired number of sample counts (Default: 750) and the desired orientation.
 
# [Motive → Trackables pane] Set the desired number of sample counts (Default: 750) and the desired orientation.
 
# [Motive → Trackables pane] Press start to initiate the sampling process.
 
# [Motive → Trackables pane] Press start to initiate the sampling process.

Revision as of 14:55, 13 December 2017

Main PageTrackables pane

Rigid Body Refinement

New in Motive 2.0
Using the RigidBody Refinement tool for improving asset definitions.

Rigid body refinement tool improves the accuracy of rigid body calculation in Motive. When a rigid body asset is initially created, Motive references only a single frame for defining the rigid body definition. The rigid body refinement tool allows Motive to collect additional samples in the live mode for achieving more accurate tracking results. More specifically, this feature improves the calculation of expected marker locations of the rigid body as well as position and orientation of the rigid body itself.

Info2.png

This feature is supported in Live Mode only.

Follow the below steps to refine rigid body definition in Motive:

Refinement Steps

  1. Under Tools tab open the Trackables pane.
  2. In Live mode, select an existing rigid body asset that you wish to refine.
  3. Hold the selected rigid body at the center of the capture volume so that as many cameras as possible can clearly capture the markers on the rigid body.
  4. Under the Refine Samples entry, Set the number of sample frame that you wish to capture for the refining process.
  5. Press Start Refine in the Trackables pane and the
  6. Slowly rotate the rigid body to collect samples ranging rigid body orientations.
  7. Once all necessary samples are collected, the refinement results will be displayed.
Rigid body refinement feature


HMD Calibration


New in Motive 2.0

The HMD calibration feature allows you to calibrate an HMD rigid body so that its pivot point is placed right at the proper location for VR applications. It utilizes both the OptiTrack mocap system and the Oculus Tracker for precisely calculating the location of the pivot point of an Oculus HMD. When using this feature, both systems must be tracking the HMD rigid body.

Info2.png

  • The HMD calibration feature supports Oculus HMDs only.
  • Both Oculus tracker and OptiTrack camera system must be tracking the HMD simultaneously. The Frontal plane of the HMD must be exposed for the Oculus Tracker to track the HMD.
  • This feature works only in Live mode.

Steps

  1. Connect the Oculus Tracker and have the Oculus software running in the background.
  2. Launch Motive.
  3. [Motive] Create a rigid body asset from the markers on the oculus HMD. Read: Creating Rigid Body.
  4. [Motive] Open the Trackables pane. Tools → Trackables → HMD Calibration tab
  5. [Motive] Select the HMD rigid body. Under Detected Type, it should indicate Custom RigidBody.
  6. [Motive → Trackables pane] Set the desired number of sample counts (Default: 750) and the desired orientation.
  7. [Motive → Trackables pane] Press start to initiate the sampling process.
  8. [Motive → Trackables pane] During calibration, make sure both the mocap system and the Oculus Tracker is tracking the HMD.
  9. [Motive → Trackables pane] Once it starts collecting the samples, point the HMD towards the Tracker and slowly rotate it and sample different orientations.
  10. [Motive → Trackables pane] When it finishes collecting samples, it will display the offset distance, in mm, between pivot point position detected by oculus and the motion capture system.
  11. [Motive → Trackables pane] If the results are satisfying, press Apply to calibrate the HMD rigid body.