Version:
Motive 2.2
Motive 2.1
Motive 2.0
Motive 1.10
Navigation
Main page
Tutorial Videos
Page References
Quick Start Guides
Getting Started
Precision Capture
Active Marker Tracking
Hardware Setup
Overview
Prepare Setup Area
Camera Placement
Camera Mount Structures
Cabling and Wiring
Aiming and Focusing
Motive Documentation
What's New
Overview
Installation
Motive Basics
Calibration
Markers
Assets
Rigid Body Tracking
Skeleton Tracking
Camera Video Types
Data Recording
Data Types
Reconstruction and 2D Mode
Labeling
Data Editing
Data Export
Data Streaming
Motive Hotkeys
Motive Batch Processor
Motive UI Pages
Application Settings pane
Calibration pane
Command Bar
Control Deck
Data Management pane
Data Streaming pane
Devices pane
Edit Tools pane
Graph View pane
Labeling pane
Markerset pane
Rigid Body pane
Skeleton pane
Synchronization pane
Timeline
Toolbar
Viewport
Status Panel
Plugins
Unity
Unreal Engine
Motion Builder
Maya
External Device Setup
Sync Configuration
AMTI Force Plate
Bertec Force Plate
NI-DAQ Devices
Peripheral API
Developer Tools
Overview
Motive API
NatNet SDK
Camera SDK
This wiki is intended for older versions of Motive. For the latest documentation, please refer to
docs.optitrack.com
Baseline + 13 Additional Markers (50)
Back to the Baseline Markerset page
Front view of the Baseline + 13 Additional Markers (50) markerset.
Back view of the Baseline + 13 Additional Markers (50) markerset.
Baseline + 13 Additional Markers (50) Placements
Head Markers
Label
Related Segment
Description
HeadTop
Head
Place the marker on the head tip.
HeadFront
Head
Place the marker at the center of the forehead.
HeadLeft / HeadRight
Head
Place markers on each side of the head (left and right), slightly above the ear. For better tracking results, the marker arrangement formed by HeadLeft, HeadRight, and HeadFront should form an asymmetrical arrangement. To achieve this, you can introduce a slight offset to one of the markers placed on the side, either HeadLeft or HeadRight marker.
Torso Markers
Label
Related Segment
Description
BackTop
Torso
Place the marker on the spine right below the neck. For best results, LUArmHigh-LShoulderBack-BackTop-RshoulderBack-RUArmHigh markers should align roughly in a straight line when the actor is in T-pose. Also, note that this marker must be placed at an elevation higher than the chest marker for the torso segment to be tracked properly.
Chest
Torso
Place the marker at the center of the sternum, about 5 cm below where the neck starts.
BackLeft
Torso
These two markers are located symmetrically on each side of the back, slightly below the lowest end of the shoulder blade (scapular bone).
BackRight
Torso
Waist Markers
Note that the waist markers are the key markers in modeling the pelvis bone, which is the major segment governing the other subsequent skeleton segments. For best results, avoid placing the waist markers in a rectangle shape. When tracking multiple actors with similar proportions, introduce an offset to one of the WaistBack marker, or the WaistCMarker (included only with the 13 additional markerset), to create an asymmetrical arrangements.
Label
Related Segment
Description
WaistLFront
Pelvis
Placed the marker on the protruding bone located on the front of the pelvis (left/right anterior iliac spine bone). The prominence can be palpated from left and right side of the waist.
WaistRFront
Pelvis
WaistLBack
Pelvis
Place the WaistLBack and WaistRBack markers above left/right hip; about 10 cm above the hip joint.
WaistRBack
Pelvis
Shoulder Markers
When placing the shoulder markers, ask the actor to stand in the
T-pose
in order to place the markers on accurate locations. It could also be helpful to ask the actor to do few rounds of arm abduction and adduction to palpate for the shoulder axis. These markers determine the width of the shoulder and respective relationship with the upper arm segment.
Label
Related Segment
Description
LShoulderBack
Shoulder
Place the marker on the shoulder joint (glenohumeral joint) on the back.
RShoulderBack
Shoulder
LShoulderTop
Shoulder
Place the marker at the top of each shoulder where you can palpate the protruding bone, which is usually located just before where the upper arm start when in T-pose. More specifically, the prominence is on the distal end of the clavicle bone (acrominoclavicular joint).
RShoulderTop
Shoulder
Arm Markers
Label
Related Segment
Description
LElbowOut
Upper Arm
Place the marker on the lateral side of the elbow joint, slightly towards the upper arm. More specifically, on the lateral epicondyle of the distal end of the humerous. Ask the actor to flex and extend the arm few times to confirm that markers are placed along the elbow axis and maintain stationary throughout the range of motion cycles.
RElbowOut
Upper Arm
LUArmHigh
Upper Arm
Place the marker on the back of the upper arm near the groove between the triceps. For best results, LUArmHigh, LShoulderBack, BackTop, RshoulderNack, and RUArmHigh should align roughly in a straight line when in T-pose.
RUArmHigh
Upper Arm
Hand Markers
For best results, place the hand markers so that the shape of the marker arrangement is asymmetrical itself and also unique to the shape on the other hand. Since the wrist marker placement is fixed along the wrist axis, offset the HandOut or the HandIn markers to create the unique arrangements. For more robust and simple tracking, hand rigid-bodies can be attached on the hand to replace the markers and guarantee the asymmetrical and non-deforming marker placement.
Label
Related Segment
Description
LWristOut
Fore Arm / Hand
Place the marker on the outside (lateral side) of the wrist axis. (distal end of the radius bone). Note that the wrist axis is not always located on the protruding bone but 1-2 cm more towards the hand.
RWristOut
Fore Arm / Hand
LWristIn
Fore Arm / Hand
Place the marker on the inner prominence (medial side) of the wrist axis (distal end of the ulnar bone).
RWristIn
Fore Arm / Hand
LHandOut
Hand
Place the marker slightly below the pinky knuckle. More specifically, between distal end of the fifth and fourth mertacarpal bones.
RHandOut
Hand
Leg Markers
Label
Related Segment
Description
LThighFront
Upper Leg
Place the marker on the front side of the thigh, along the midline. For best results, slightly offset the height of the left and right markers to introduce the asymmetry.
RThighFront
Upper Leg
LKneeOut
Upper Leg
Place the marker on the outter prominence of the knee joint; on the lateral epicondyle of the femur. Palpate the knee for the protruding bone from the upper leg, and place it right on the axis. Ask the actor to flex and extend the knee few times to confirm that the markers are placed along the axis and maintain stationary throughout the range of motion cycles.
RKneeOut
Upper Leg
LShin
Lower Leg
Place the marker on the shin bone; on the midline of the lower leg. For best results, slightly offset the height of the left and right markers to introduce the asymmetry.
RShin
Lower Leg
Foot Markers
Label
Related Segment
Description
LAnkleOut
Lower Leg/Foot
Place the marker on the protruding bone outside of the ankle joint; on the lateral end of the malleolus bone.
RAnkleOut
Lower Leg/Foot
LToeOut
Foot
Place the marker just before the little toe joint; on the distal end of the fifth metatarsal bone.
RToeOut
Foot
LToeIn
Foot
Place the marker just before the big toe joint; on the distal end of the first metatarsal bone.
RToeIn
Foot
Hinged Toe Markers
Hinged toe markersets create toe segments in the skeleton. Two additional markers are added to each foot, one on the toe-tip and another on the heel. The hinged toe markers are included in all baseline markersets except for Baseline (37) and Upper Body markersets.
Label
Related Segment
Description
LHeel
Foot
Place at the center of the heel.
RHeel
Foot
LToeTip
Toe
Place the marker on the tip of the second toe; next to the big toe.
RToeTip
Toe
Additional Markers in the Baseline (50)
In this marker set, there are multiple additional markers added to the Baseline (37). The marker placement can be found in the
Skeleton Pane
. The following chart provides additional explanations on the marker locations.
Label
Related Segment
Description
HeadLeft
Head
Included in place of the
HeadSide
marker. Place the marker on the left side of the head, slight above the ear. For best tracking results, place either the HeadLeft marker or the HeadRight marker slightly further behind the ear in order to introduce more distinct asymmetry to left and right side.
HeadRight
Head
Included in place of the
HeadSide
marker. Place the marker on the right side of the head, slightly above the ear. See above descriptions for the HeadLeft marker for comments on the asymmetry.
ChestTop
Torso
Included in place of the
Chest
marker. Place the marker at the center of the chest (sternum); approximately 5 cm below where the neck starts.
ChestLow
Torso
Included in place of the
Chest
marker. Place the marker where bottom of the two rib cages conjoin; the lowest end of the sternum (xiphoid process).
WaistCBack
Pelvis
Place the marker about 5 cm above the pelvis bone, near the center of the waist back (on the spine) with a slight offset towards the right (or left). This is usually located slightly above one of the dimples located on the waist back (posterior iliac spine bone).
LFArm
Fore Arm
Place the marker on the front side of the forearm while in T-pose. For best results, slightly offset the left and right forearm markers to introduce the asymmetry on each side.
RFArm
Fore Arm
LHandIn
Hand
Place the marker below the knuckle of the index finger.
RHandIn
Hand
LThighSide
Upper Leg
Place the marker on the lateral side of the thigh. Ideally, L/R ThighSide, L/R KneeOut, and L/R AnkleOut markers should be aligned roughly in a straight line.
RThighSide
Upper Leg
Categories
:
Baseline
Markerset
This page was last edited on 23 January 2017, at 18:17.
All data and information contained in or disclosed by this wiki is proprietary information of NaturalPoint Corporation and all rights therein are expressly reserved. By accepting this material the recipient agrees that this material and the information contained therein is held in confidence and in trust and will not be used, copied, reproduced in whole or in part, nor its contents revealed in any manner to others without the express written permission of NaturalPoint Corporation. Information in this document is preliminary and subject to change and does not represent a commitment on the part of NaturalPoint Corporation.